Checking the operation of the sensor
Switch off the ignition. Move the rubber cover of the ignition distributor connector, connect the LED probe to the terminals «2» (green-white wire) And «3» (red-black wire) connector (pic. 2-133) and briefly turn on the starter. In this case, the probe LED should give flashes. If this does not happen, check the camshaft angle sensor.
Checking the sensor supply voltage
Switch off the ignition. Disconnect the sensor connector, connect a voltmeter to the terminals «1» and «3» (pic. 2-134) cable part of the connector, turn on the ignition and check the voltage with a voltmeter, which must be at least 10 V.