To check the operation of the stopper, set the selector lever to the "P" position and apply 12 V to the stopper electromagnet. The stopper should lock the selector lever.
Disconnect the voltage from the stopper. The selector lever should move to all positions. The stopper plunger should not engage with the selector lever. Set the selector lever to position "N" and check the operation of the stopper as indicated for position "P".