Drain the coolant into a container.
Disconnect hose clamps, remove hoses.
Disconnect the ends of the hoses with a screwdriver, which is inserted between the hose and the nozzle, then carefully use the screwdriver as a lever.
The latest models use hose clamps that can be removed with pliers without any difficulty. These clips can only be used on water hoses that have already been installed with clips before. In case of doubt, use threaded brackets
Put the new hoses on the nozzles so that they cannot slip off again.
Screw in the threaded clamps, but not too tight, otherwise the threads may be damaged.