Work order
NOTE: When dismantling the gland, make sure that the seating surface is not damaged.
Carefully remove the old O-ring using a puller T20143/2 (pic. 2.177).
Wipe off any remaining oil on the crankshaft journal with a clean rag.
Connect mounting sleeve T10207/1 and mounting sleeve T10207/2. Put the stuffing box A all the way onto the mounting sleeve Т10207/2 (rice. 2.175).
Separate the mounting sleeves.
Install the T10207/2 mounting sleeve together with the oil seal on the crankshaft seal and tighten the knurled bolts A by hand.
Press the stuffing box using the mounting sleeve T1207 / 3 until it stops (rice. 2.176).
Further installation is carried out in the reverse order.