Pic. 2.204. Fuel supply module cover and control unit
Remove cover 1 with fuel pump control unit 2 from the fuel supply module (pic. 2.204).
Pic. 2.205. Plug and fuel line
Disconnect 5-pin plug A and fuel line B from the flange (pic. 2.205).
Note: To disconnect the fuel line, press the retaining ring.
Note: On vehicles with an additional heater, the plug and fuel line must also be disconnected from the metering pump.
Open the retaining ring with a key.
Raise the sensor flange.
Insert the extraction hose of the fuel extraction device as far as possible into the fuel tank and extract the fuel.
If it was only necessary to pump out the fuel from the tank, the sensor flange must be reinstalled.