Verification procedure
Open the cap of the expansion tank of the cooling system.
Warning: When opening the expansion tank, hot steam may escape. To avoid eye injury and scalding, wear protective glasses and special clothing. Cover the tank lid with a rag and carefully open it.
Fig. 2.184. Tester installation
Place the cooling system tester with adapter on the expansion tank (fig. 2.184).
View the original on this resource [www.VWManual.ru]
Using the hand tester pump, create an excess pressure of approximately 1.0 bar.
If the pressure drops, find the leak and fix it.
Checking the pressure reducing valve in the expansion tank cap
Fig. 2.185. Checking the pressure reducing valve in the expansion tank cap
Place the cooling system tester with adapter on the expansion tank cap (fig. 2.185).
Activate the hand pump.
The pressure reducing valve should open at an excess pressure of 1.4 to 1.6 bar.