Place the instrument and starter switch key in position «Turned off». Disconnect the MCC wire harness connector (pic. 3-55). Connect an ohmmeter to the leads «1» and «7» pads and check the resistance, which should be in the range of 0.4-1.1 kOhm. If the value deviates, replace the regulator.