To remove, drain the coolant from the cooling system. Disconnect the wire from the negative battery terminal. Remove generator. Disconnect hoses from coolant pump. Loosen the pump mounting bolts. Take out the pump. Remove the sealing collar, which must not be reused. Thoroughly clean the surfaces to which the cuff is attached.
Install a new seal before installation. Install the coolant pump to the cylinder block. Tighten the pump mounting bolts. Connect the hoses to the coolant pump. Install generator. Connect the wire to the negative terminal of the battery. Fill the system with coolant.