Note: Ignition coil housings with output stages have been modified. Therefore, ignition coil data can only be removed and installed using puller -T10094A-. The previous puller -T10094- can also be used further if it is modified in this way. as described below.
Remove the marked area -2- with a suitable tool to obtain a new nominal dimension -B- 13 mm. Mark the designation of the tool additionally with the letter A -1-.
Removing
Raise the engine cover at points -1 - and remove the cover by moving it forward in the direction of the arrow-. Unscrew securing bolts -1- for crankcase breather and non-return valve. Remove connector -2- from turbocharger wastegate N249- and hose connection -3-,
Position puller -T10094 A- on ignition coil with output stage -arrow-.
Slightly pull out the ignition coil with the output stage. Position assembly tool -T10118- as shown. Carefully loosen the connector lock and disconnect the connector.
Installation
Fit puller -T10094 A- to ignition coil with output stage. Push the connector onto the ignition coil with the output stage until it snaps into place. Press ignition coil with output stage in direction -arrow- into cylinder head.
Further installation is carried out in the reverse order. The tightening torques of the bolts for fastening the crankcase ventilation connecting fitting and the check valve: 10 Nm.
Control data, spark plugs
Engine code | CAVA |
The order of operation of the cylinders | 1-3-4-2 |
Spark plug | |
VW part number | 101 90S 626 |
Gap between electrodes | 0.8...0.9 mm |
Torque | 25 Nm |