When the working fluid decreases from the tank, it is usually necessary to check the tightness of the system.
In the event of leaks in the pipe connection area, the lines and their connections must first be checked for leaks and, if necessary, tightened.
Attention! The pumps supplied as spare parts are free of oil. Therefore, before installation, be sure to fill the pump G 002 000 Hydraulikol and turn it by hand, otherwise noise or damage to the pump may occur during operation.
Repair of the rotary pump is not provided.
Removing
1. Clamp the hoses (3) And (4) hose clamps (see fig. VC6.017).
2. Loosen the poly V-belt tension.
3. Disconnect the hoses (3) And (4).
4. Collect the leaking oil in a container.
5. Remove the bolts (9) and remove the pump.
Installation
Installation is in the reverse order.