Instructions: Various types of quick couplings and spring clamps are used to connect the pressurization system hoses. When installing quick couplings, observe the relevant instructions. The boost system must be airtight.
Caution: Always tighten the screw clamps on the charge air lines to 5.5 Nm. Too low or too high a tightening torque can cause the charge air hose to break off the charge air pipe while driving.
- 1 - 5 Nm
- 2 - Intercooler support
- 3 - Intercooler. To remove, place the radiator frame in the service position
- 4 - Connecting hose,» cold «side, bottom
- 5 - Screw clamp, 5.5 Nm
- 6 - To throttle valve control module -J338-
- 7 - Connecting hose,» cold «side, top
- 8 - Charge pressure sender -G31- with intake air temperature sender -G42-
- 9 - 2 Nm
- 10 - Rubber element, replace if damaged
- 11 - 8 Nm
- 12 - Air intake pipe,» cold «side
- 13 - Connecting hose, «hot» side, top
- 14 - From the turbocharger
- 15 - Intake air pipe, «hot» side
- 16 - Connecting hose, «hot» side, bottom