Contents: Removal ↓ Installation ↓
Removal
1. Disconnect the negative cable from the battery.
2. Disconnect the wiring connector 1 of circuit 50 (Fig. 12.1). Remove the plastic cover 2 and disconnect the wire from terminal 30 of the starter solenoid.

3. Unscrew bolt 1, nut 4, bolts 3 and 2 (Fig. 12.2).

4. Remove the starter.
Installation
5. Installation is carried out in the reverse order of removal.
Tightening torques: bolt 1 - 45 Nm, bolt 3 - 60 Nm, nut 4 - 60 Nm.